Architectural Technology
CADD26909 - Architectural
Drafting 3- CAD
- 50 mm white gravel on protected membrane
with 75 mm rigid insulation on a 38 mm steel deck sloped 1% on open web steel
joists (OWSJ).
- Green mass on 100 mm growth medium, 25 mm roof fleece, 25 mm drainage layer, top and bottom membranes
with 100 mm rigid insulation on a 65 mm steel deck sloped 1% on open web steel
joists (OWSJ).
- 65mm poured concrete
slab with 150x150W.W.F. on 38mm steel decking, on OWSJ on steel beams and
columns.
- 100 mm concrete slab
on 50 mm rigid insulation on vapour barrier on compacted granular fill.
- 125 mm fibre reinforced
poured concrete slab, 25 mm rigid insulation on vapour barrier on compacted
granular fill.
- a) Office:
- EIFS (exterior insulated
finish system)
Granstone Finish on rigid insulation, OSB sheathing on metal studs with vapour barrier and gypsum wall board.
- b) Warehouse:
- Precast Concrete.
Insulated concrete sandwich panels with 100 mm backer panel, 75 mm rigid
Insulation, and 75 mm ribbed exterior panel.
- Interior
Columns:
- Concrete piers and footings under column where required. Concrete caissons may be used instead of footings in some locations.
- Exterior Columns:
- Poured concrete piers
and footings where required.
- Typical:
- Reinforced poured concrete
cap wall on a poured concrete trench footing.
- Loading Dock:
- 300mm poured concrete
foundation wall on trench footing.